文章摘要
Liu Tao(刘涛),Zuo Zhibing,Yin Zhigang.[J].高技术通讯(英文),2019,25(4):378~385
Research on double differential pressure dynamic flowmeter
  
DOI:doi:10.3772/j.issn.1006-6748.2019.04.005
中文关键词: 
英文关键词: dynamic flowmeter, double differential pressure, contrast experiment, coefficient correction
基金项目:
Author NameAffiliation
Liu Tao(刘涛)  
Zuo Zhibing  
Yin Zhigang  
Hits: 1616
Download times: 1375
中文摘要:
      
英文摘要:
      When testing an electrohydraulic proportional valve, it is necessary to test the high frequency dynamic flow with bias. Because of the limitation of the piston stroke, a no-load hydraulic cylinder is only suitable for a reciprocating symmetrical dynamic flow test. Since the traditional differential pressure flowmeter is affected by viscosity and inertia of the fluid, it is only suitable for measuring steady flow. Therefore, a new type of double pressure differential dynamic flowmeter is designed to improve the traditional differential pressure flowmeter. The influence of fluid viscosity and inertia in the flow process are negated by subtracting the differential pressure in section expansion from the differential pressure in section contraction. The double differential pressure flowmeter is modeled and a flow meter prototype is designed. Then, the flow coefficients are identified and corrected by a practical test. Finally, the dynamic performance and steady-state precision of the flowmeter are verified by comparing with the test results of the no-load hydraulic cylinder. The double differential pressure dynamic flowmeter is proven to measure dynamic flow accurately, especially at higher dynamic frequencies.
View Full Text   View/Add Comment  Download reader
Close

分享按钮