An intraoperative lumbar neurological force monitoring system with high-density flexible pressure sensor array |
|
DOI:10.3772/j.issn.1006-6748.2020.04.011 |
中文关键词: |
英文关键词: nerve root retractor, flexible sensor, force monitoring, lumbar disc herniation (LDH) surgery |
基金项目: |
Author Name | Affiliation | Zhang Qi (张琪)* ** | (*State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P.R.China)
(**University of Chinese Academy of Sciences, Beijing 100049, P.R.China) | Zhang Xu* | (*State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P.R.China) | Li Caili*** | (***Academy of Advanced Semiconductors and Intelligence Technologies, Haining 314400, P.R.China) | Liu Jianchao*** | (***Academy of Advanced Semiconductors and Intelligence Technologies, Haining 314400, P.R.China) | Liu Ming* | (*State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P.R.China) | Yuan Fang* | (*State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P.R.China) | Chen Hongda* | (*State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, P.R.China) |
|
Hits: 1668 |
Download times: 1653 |
中文摘要: |
|
英文摘要: |
In the surgery of lumbar disc herniation (LDH), the nerve root retractor is used to pull the nerve root to prevent damage. The traditional medical nerve root retractor cannot quantify the force on the nerve root. In order to improve the nerve root retractor, this paper proposes an intraoperative lumbar neurological force monitoring system. The core module of this system is the improved nerve root retractor equipped with the high density flexible pressure sensor array. The high density microneedle array and multiple pressure detection units are used in the pressure sensor to realise sensitive pressure monitoring in a narrow surgical operation area. The sensing area is 4mm×17mm, including 6 detection units. The sensitivity of sensor is 67.30%/N in the range of 0-5N. This system is used for in vitro animal experiments, which can continuously detect pressure. |